Barco R9000904 Projector User Manual


 
AC power connection
6-2 5976284 BARCOGRAPHICS 808s 150403
AC Power check
The power voltage is autoranging between 100V(-10%) and
240V(+6%).
If the indicated voltage is different from that of the wall outlet, call a
qualified technician for power adaptation of the projector.
Fuse replacement
Follow the procedure as described below to replace the fuses :
WARNING: turn off the projector and be sure the AC Power
Cord is unplugged before starting the procedure !
Open the top cover (see 'Access to controls' on p.4-1).
Unscrew the retaining screws of the AC power input board and
remove this board.
Pull out the fuses and place the correct fuses in their sockets. See
the table below for the correct type of fuses.
Reinsert the power input board and secure it with the retaining
screws.
Fuses
AC Power
input board
1
2
Warning !
For continued protection against fire hazard :
Replace with the same type of fuse.
Refer replacement to qualified service personnel.
Fuses Order Number
T10A (2x) R314521
F10A (1x) R314155