Barco R9000904 Projector User Manual


 
Source connections
7-2 5976284 BARCOGRAPHICS 808s 150403
Connecting a RGB Analog source to Port 3
Connect a RGB Analog signal via an interface (e.g. RGB 120MHz
interface, part number 98 26570) to Port 3: RGB analog input with
automatic sync detection (Separate H and V sync inputs, with
composite sync input or with sync signals on green).
Pin configuration of the D9 (male) connector of the Analog input :
1 not connected
2 ground RGBS
3 RED
4 GREEN
5 BLUE
6 ground RGBS
7 ground RGBS
8 Horizontal /composite sync
9 Vertical sync
To select the RGB analog Input :
Press the numeric button 3 on the RCU or the local keypad.
S1 Force Negative Sync
(ON=yes)
R81
Hsync
R101
Vsync
R41
(Blue)
R21
(Green)
R1
(Red)
S2 Blue in Green (ON=yes)
Line termination 75 W resistors
Locations of the Termination Resistors and Switches
on the RGB Input Auto Sync Tracking Module
When changing a switch position or removing a resistor, turn off the
projector and unplug the power cord from the wall outlet.
75 W Termination resistors
In case of chaining (loop-through) the projectors, the 75W line
termination resistors must be removed from the RGB Input Auto Sync
Tracking Module when the projector is NOT the last unit in the chain.
In case of a stand-alone projector, do not remove the resistors.
75 W resistors on the module : line terminated.
75 W resistors removed : line not terminated.
RGB 120MHz interface