Barco R9002328 Projector User Manual


 
R5975059A BARCOVISION 708 200498
SERVICE MODE
SERVICE MODE
R5975059A BARCOVISION 708 200498
SERVICE MODE
SERVICE MODE
9-19
9-19
Select with ê or é
then <ENTER>
<EXIT> to return.
CRT run in cycle
The CRT run in cycle option can only be activated when memory blocks on an
internal # pattern are available. When one or more such blocks are available, a
flashing white image (5sec on, 5 sec off) is generated and that for 5 min on the
first internal block. In the next 5 min, a second internal block will be used to generate
the flashing white image. The image will also be shifted in a vertical way to prevent
a CRT burn in. To quit the CRT run in cycle option, press EXIT.
Highlight 'CRT run in cycle' with
the control disc and press ENTER
to start.
If a memory block adjusted on an
internal # pattern is available, the
CRT run in cycle will start when
pressing ENTER. If no such a block
is available, the projector cannot
run the CRT run in option and leaves
the adjustment mode.
If you still want to run CRT run in
cycle, create first a memory block
on an internal # pattern and restart
the CRT run in option.
ENTER starts the 'CRT run in' when an
internal generated # pattern is available.
EXIT returns to the Path Selection main
menu.
ENTER selects the CRT run in cycle option.
EXIT returns to the Path Selection main
menu.
COMMON SETTINGS
G2 ADJUSTMENT
CRT RUN IN CYCLE
PROJECTOR WARM UP
CRT DRIVE MODE
A flashing white pattern
will be generated until
<EXIT> is pressed.
The projector only uses
memory blocks adjusted
on an internal # pattern;
if no such block is
available, the projector
cant run the procedure
and leaves the adjustment
mode.
CRT RUN IN CYCLE
<ENTER> to continue
<EXIT> to cancel
Select with ê or é
then <ENTER>
<EXIT> to return.
CRT run in cycle
The CRT run in cycle option can only be activated when memory blocks on an
internal # pattern are available. When one or more such blocks are available, a
flashing white image (5sec on, 5 sec off) is generated and that for 5 min on the
first internal block. In the next 5 min, a second internal block will be used to generate
the flashing white image. The image will also be shifted in a vertical way to prevent
a CRT burn in. To quit the CRT run in cycle option, press EXIT.
Highlight 'CRT run in cycle' with
the control disc and press ENTER
to start.
If a memory block adjusted on an
internal # pattern is available, the
CRT run in cycle will start when
pressing ENTER. If no such a block
is available, the projector cannot
run the CRT run in option and leaves
the adjustment mode.
If you still want to run CRT run in
cycle, create first a memory block
on an internal # pattern and restart
the CRT run in option.
ENTER starts the 'CRT run in' when an
internal generated # pattern is available.
EXIT returns to the Path Selection main
menu.
ENTER selects the CRT run in cycle option.
EXIT returns to the Path Selection main
menu.
COMMON SETTINGS
G2 ADJUSTMENT
CRT RUN IN CYCLE
PROJECTOR WARM UP
CRT DRIVE MODE
A flashing white pattern
will be generated until
<EXIT> is pressed.
The projector only uses
memory blocks adjusted
on an internal # pattern;
if no such block is
available, the projector
cant run the procedure
and leaves the adjustment
mode.
CRT RUN IN CYCLE
<ENTER> to continue
<EXIT> to cancel