Cabletron Systems 7H02-06 Switch User Manual


 
2-2
Network Requirements
Transmitter power parameters are listed in Table 2-2.
The link distance is up to 2 kilometers on the multimode fiber-optic
cable as specified by ANSI MMF-PMD.
Note:
The link distance for Full Duplex is 2km; if Full Duplex is not being
utilized, the link distance is 400 meters.
2.3 FE-100TX AND FIXED RJ45 PORTS
The FE-100TX has an RJ45 connector supporting a Category 5
Unshielded Twisted Pair (UTP) connection. The pinouts for the FE-
100TX and FE-100FX are listed in Table 2-3.
Table 2-2. Transmitter Power Parameters
Parameter
Typical
Value
Worst
Case
Worst
Case
Budget
Typical
Budget
50/125
µ
m
fiber
-13.0 dBm -15.0 dBm 13.0 dB 17.5 dB
62.5/125
µ
m fiber
-10.0 dBm -12.0 dBm 16.0 dB 20.5 dB
100/140
µ
m fiber
-7.0 dBm -9.0 dBm 19.0 dB 23.5 dB
Error Rate Better than
10