Cabletron Systems SFCS-200BX Switch User Manual


 
A-18
Troubleshooting
A.3.3 Switch Information
On the host, at a command line, type the following commands and note the
responses:
atmstat fa0 command
netstat -ai command
asxmon command
cport command
Log in to the ATM Management Interface (AMI) and open a session on the
switch fabric to check the following:
configuration spans show
configuration port show
configuration uni30 show
Configuration of Network Modules (TAXI, DS3, DS1, SONET, E3, E1,
and/or J2)
Typical responses are shown under each command. The responses from these
commands enables support to gather sufficient information to resolve the
majority of problems.
atmstat fa0
PHY/ATM/AAL statistics:
Output Input Errors
ATM AAL* ATM AAL* 4B5B 4B5B ATM AAL* AAL*
Cells CS-PDUs Cells CS-PDUs Framing Hdr-CRC VPI/VCI Pay-CRC Proto
476058 469354 276580 273789 0 0 0 0 0
netstat -ai
Name Mtu Network Address Ipkts Ierrs Opkts Oerrs Coll
ec0 1500 fore gar-eth 1174803 39928 509563 0 107117
ALL-SYSTEMS.MCAST.N
08:00:69:07:e3:93
fa0 9188 198.29.38 198.29.38.206 0 0 0 0 0
ALL-SYSTEMS.MCAST.N
qaa0 9180 fore-sw 198.29.22.206 0 0 0 0 0
qaa1*9180 none none 0 0 0 0 0
lo0 8304 loopback localhost 32072 0 32072 0 0
ALL-SYSTEMS.MCAST.N