Cabletron Systems STHI Switch User Manual


 
The SNMP Tool Screen
Page 5-27
Token Errors 4
A Token Error may indicate that an active monitor either has detected a
recirculating frame or token, or has found that its Timer Valid
Transmission (TVX) time has expired before any token has been detected
circulating on the ring (i.e.: a lost frame error has occurred). The active
monitor is responsible for purging the ring and issuing new tokens in
response to these errors.
Frequency Errors 5
A Frequency Error may indicate that the frequency of the incoming signal
deviates excessively from that of the reporting station’s onboard crystal
oscillator. When frequency errors are detected, the ring enters the monitor
contention process to establish a new active monitor.
5.9 The SNMP Tool Screen
Access the SNMP Tool screen (Figure 5-14) from the Main Menu.
Figure 5-14. SNMP Tool Screen
Through the SNMP Tool screen, the user can access information stored in
the STHI hub’s Management Information Base (MIB). MIBs and their
objects are logically arranged as trees with subsequent branches and
leaves; each leaf is a MIB object. One leaf, for example, contains the hub’s
STHI LOCAL MANAGEMENT Flash Image Version: 1.00.00
SNMP TOOLS
COMMUNITY NAME: public
OID PREPEND: 1.3.6.1
GET SET GETNEXT WALK RECALL OID STEP CYCLES REPEAT
F6 F7 F8 F9
RETURN
F10