COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 SELF DIAGNOSIS
6-45 T
E580
0000 The delivery tray upper limit sensor (S13) goes ON while the delivery tray
ascent/descent motor (M5) is in operation.
The clock signal of the delivery tray ascent/descent motor clock sensor (S9)
is not detected 15 times or more within 0.8 sec while the delivery tray as-
cent/descent motor (M5) is in operation.
The delivery tray paper height sensor (S10) does not go ON 4 sec after the
delivery tray ascent/descent motor (M5) starts to move up.
The delivery tray paper height sensor (S10) does not go OFF 4 sec after the
delivery tray ascent/descent motor (M5) starts to move down.
Cause The delivery tray ascent/descent motor (M5) is faulty. The delivery tray pa-
per height sensor (S10) is faulty, the harness is disconnected, or an open
circuit exits. The delivery tray ascent/descent motor lock sensor (S9) is
faulty, the connector is disconnected, or an open circuit exits. The delivery
tray ascent/descent motor is subjected to an excess load. The finisher con-
troller PCB is faulty.
E585
0000 At the start of the motor CCW operation, the stack handling motor (M2)
may be driven for a specific number of rotations; however, the stack deliv-
ery lever home position sensor (S8) does not go ON.
Cause The stack handling motor (M2) is faulty. The stack delivery lever home po-
sition sensor (S8) is faulty, the connector is disconnected, or an open circuit
exits. The stack handling motor (M2) relay harness is faulty. The return
roller is faulty.