Advanced Operations
90
E
Procedure
Step 1. Press ° and <PGM-6> icon to turn Program 6 mode and press `.
Step 2. Select an appropriate job and press `.
Step 1. screen Step 2. screen
Step 3. Select an appropriate job and press `. If the job requires range destination, Step 4 screen will appear.
Step 4. Enter the start/end range and press `.
Step 3. screen Step 4. screen
Step 5. Press
\ repeatedly to return to the “Step 1. screen”.
Report example (It is necessary to connect optional remote printer to print out these reports. )
Unit price and quantity
PLU unit price
PLU001 0001-004
— PLU descriptor/Record No./File No.
@12.34
— Unit Price
0001-055
— Record No./File No.(Shift PLU)
@2.00
— Shift 2 PLU unit price
:
@8.00
PLU002 0002-004
@1.00
PLU 2nd @
PLU001 0001-054
— PLU 2nd descriptor/Record No./File No.
2 @23.45
— Unit quantity/2nd unit Price
PLU002 0002-054
1 @10.00
PLU003 0003-054
0 @2.00
P6
C
01 31-10-04 05:55 PM 000123
PGM-6
1.PGM Read Report
0.00
PGM Read Report
Unit Price/Qty
1.PLU
2.PLU 2nd@
3.Sub-Department
4.Department
5.Function key
0.00
PLU
Enter Start range 0
End range 0
OK? YES
0.00
PGM Read Report
PGM Read Report
1.Unit Price/Qty
2.Item Descriptor
3.Char & Message
4.Machine Feature
5.Clerk
6.Key Feature
7.Keyboard
8.Memory Alloc.
0.00