Christie Digital Systems DWU775-E Projector User Manual


 
E Series User Manual
020-000515-01 Rev. 2 (03-2013)
Section 4: Operation
4-40
The projector automatically detects the lamp life. When the lamp life is
nearing the end of use, you will receive a warning message. When you see
this message, please change the lamp as soon as possible. Make sure the
projector has been cooled down for at least 30 minutes before changing the
lamp.
4.12 Install the Lamp
Note the number of the lamp that needs to be replaced on the 1. Current Lamp” menu.
Turn off the lamps:2. Turn the projector OFF and disconnect the power cord.
Allow the projector to cool down for at least 30 minutes.3.
Open the lamp door:4. Unscrew the two screws on the lamp door.
Open the lamp door located on the top-rear of the projector.5.
Remove the lamp:6. Loosen the two captive screws securing the lamp.
Lift up the lamp by grasping handle and remove the lamp module slowly and carefully. 7.
Install the new lamp:8. Replace the lamp with a new one and tighten two screws. Make
sure the lamp is set properly and secure.
Close the lamp door:9. Put the Lamp Door back on and tighten two screws.
Reset the projector:10. Turn the projector ON and use “Reset Lamp Hours” after the lamp
module is replaced.
Recommend calibrating light sensor if using Constant Intensity for lamp mode.11.