Verifying FlexAttach Virtual pWWN Configuration
Restrictions
The specified virtual pWWN and the real pWWN must not be logged in.
Detailed Steps
To map pWWN to virtual pWWN, perform this task:
Verifying FlexAttach Virtual pWWN Configuration
To display FlexAttach configuration information, perform one of the following tasks:
For detailed information about the fields in the output from these commands, refer to the Cisco MDS
NX-OS Command Reference.
To view and confirm that the type and value of virtual pWWNs are correct, enter the show flex-attach
virtual-wwn command. (See
Example 8-1.)
Example 8-1 Displaying the Type and Value of Virtual pWWNs
switch# show flex-attach virtual-wwn
VIRTUAL PORT WWNS ASSIGNED TO INTERFACES
----------------------------------------------------------------------
VSAN INTERFACE VIRTUAL-PWWN AUTO LAST-CHANGE
----------------------------------------------------------------------
1 fc1/1 00:00:00:00:00:00:00:00
1 fc1/2 22:73:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/3 22:5e:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/4 22:5f:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/5 22:74:00:05:30:01:6e:1e TRUE Thu Jan 31 01:26:24 2008
1 fc1/6 22:60:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/7 22:61:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/8 22:62:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/9 22:63:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/10 22:64:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/11 22:65:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
1 fc1/12 22:66:00:05:30:01:6e:1e TRUE Thu Jan 31 01:58:52 2008
Command Purpose
Step 1
switch# config t
Enters configuration mode.
Step 2
switch# (config)# flex-attach virtual-pwwn
vpwwn
pwwn
pwwn
Maps the pWWN to the virtual pWWN.
Step 3
switch# (config)# flex-attach commit
Commits the configuration.
Command Purpose
show flex-attach virtual-wwn Displays the type and value of virtual pWWNs.
show fcns database Displays if the end device is logged with the
correct virtual WWNs.