Infortrend
D-22
General Target Events:
Alert:
SAF-TE Device:
2-Line LCD
SAFTE_: Power (_) Failure Detected
Terminal
[3F21] SAF-TE Device (_) ALERT: Power Supply Failure Detected (_)
Event Type
!Alert "Warning "Notification
What
Happens?
Power supply failure detected by SAF-TE enclosure management.
What to
Do?
Check the power supply module, contact your RAID system supplier.
2-Line LCD
SAFTE_: Fan (_) Not Installed
Terminal
[3F22] SAF-TE Device (_) ALERT: Cooling Fan Not Installed (_)
Event Type
!Alert "Warning "Notification
What
Happens?
The installed fan (_) is missing.
What to
Do?
See if the fan has been removed or a general failure has occurred.
Contact your system supplier.
2-Line LCD
SAFTE_: Fan (_) Failure Detected
Terminal
[3F22] SAF-TE Device (_) ALERT: Cooling Fan Failure Detected (_)
Event Type
!Alert "Warning "Notification
What
Happens?
The cooling fan has failed.
What to
Do?
Contact your system supplier for further diagnosis.
2-Line LCD
SAF-TE_: Elevated Temperature Alert
Terminal
[3F23] SAF-TE Device (_) ALERT: Elevated Temperature Alert (_)
Event Type
!Alert "Warning "Notification
What
Happens?
High temperature detected.
What to
Do?
High temperature may lead to malfunctioning and system failure. The
most probable cause is the cooling system failure. Contact your system
provider immediately.
2-Line LCD
SAF-TE_: UPS Power Failure
Terminal
[3F24] SAF-TE Device (_) ALERT: UPS Power Failure Detected (_)
Event Type
!Alert "Warning "Notification
What
Happens?
UPS Power Failure.
What to
Do?
If UPS protection is lost, inconsistency may occur to cached data upon
power interruption. Auto-switch to write-through cache upon the
detection of UPS failure will be available in future release of firmware.
Contact your system provider for help.