Infortrend
5-14
you can map the whole capacity to a
host LUN.
Mapping information will be displayed
on the subsequent screen. Press ENT
for two seconds to confirm the LUN
mapping.
With any of the Host ID/LUN successfully associated with a logical
capacity, the “No Host LUN” message in the main menu will change
to “Ready.”
If you want to create more host IDs, please move to section 5.11 for
more details on channel mode and channel IDs setting.
5.8 Assigning Spare Drive and Rebuild
Settings
Adding a Local Spare Drive
Press ENT for two seconds to enter the
Main Menu. Press ▼ or ▲ to select
"View and Edit SCSI Drives," then
press ENT.
SCSI drive information will be
displayed on the LCD. Press ▼ or ▲ to
select a drive that is stated as “NEW
DRV” or “USED DRV” that has not
been assigned to any logical drive, as
spare drive or failed drive, then press
ENT to select it.
Press ▼ or ▲ to select “Add Local
Spare Drive,” then press ENT.
Press ▼ or ▲ to select the logical drive
where the Local Spare Drive will be
assigned, then press ENT for two
seconds to confirm.
The message “Add Local Spare Drive
Successful” will be displayed on the
LCD.
CH=0 ID0 LUN0
MAP to LV=0 PRT=0?
View and Edit
SCSI Drives ↕
C=2 I=4 1010MB
NEW DRV SEAGATE
Add Local Spare
Drive ..
LG0 RAID5 DRV=3
2012MB GD SB=0
Add Local Spare