Configuring Your Units
You can configure your network using:
Default factory configuration – that lets you easily setup your network as a simple send/receive; or
User-defined customized configuration – that lets you set specific information about your network and allows communication with other
Cooper Bussmann BU-905U-L Series devices.
For more information on setting a user-defined customized configuration, see the User Manual.
For more information on setting the factory default configuration, refer to the Quick Start Guide included with your module.
The following table details the factory default configuration:
Signals Sent Over Radio
BU-905U-L-T (Transmitter) Sends BU-905U-L-R (Receiver)
Digital Input 1 Digital Output 1
Digital Input 2 Digital Output 2
Analog Setpoint Digital Output 3
Analog input (4-20mA) Analog output
Other Signals
BU-905U-L-T (T
ransmitter) BU-905U-L-R (Receiver)
Thermocouple Input (Not used) Communication Failure (Comes on if no messages from BU-905U-LT)
Setpoint Output (Local indication) Communication Failure (Comes on if no messages from BU-905U-LT)
System OK (On if system OK) System OK (On if system OK)