CyberResearch CPEN GX-333-X Personal Computer User Manual


 
CPEx GX-333-X CyberResearch
®
CPU Cards
32 ©Copyright 2007 CyberResearch, Inc.
Table 2-16 CN12 & CN13 USB Port Pinouts
PIN DESCRIPTION PIN DESCRIPTION
1 +5V 2 USB_GND
3 D1F- 4
USBDT3P
5 USBDT2P 6 USBDT3N
7 GND 8 +5V
Figure 2-21 CN12 and CN13 USB Combo Header
14. CN14: Coin Cell Battery Connector
Notices on Battery:
9 This 2-pin header connects to an externally mounted 3V, Lithium, cell coin battery (VARTA CR2032). The life
expectancy of the battery is approximately 7 years. Depending on the working condition, the life expectancy may be
shorter.
9 Replacing a battery is not a user operation.
9 If the battery starts to weaken and loses voltage, contact CyberResearch for a replacement module. Dispose of the used
battery properly. You may contact your local waste disposal agency for disposal instructions. Do not dispose of a used
battery with normal household waste.
WARNING!
1. Keep a used battery away from children.
2. Danger of explosion if the battery is incorrectly replaced. Only a certified module from
CYBERRESEARCH can be used as a replacement.
3. Do not expose the battery to excessive heat or fire.
4. If the battery shows signs of leakage, contact CyberResearch immediately.