USE AND FUNCTIONING
3
2. Tap Align Screen to open the Calibration screen shown in Figure 4.
3. Carefully press and briefly hold stylus on the center of the target. Repeat as the
target moves around the screen. Press the <ESC> key at any time to cancel the
stylus calibration.
4. By completing the calibration procedure you implicitly accept the new calibration
settings.
5. New calibration settings are persistently saved in registry.
Figure 4
Startup stylus calibration on Windows CE
When starting the terminal, a stylus calibration screen comes up if valid calibration
settings are not available. This happens in the following circumstances:
1. At the first startup of the terminal.
2. After restoring registry default settings using the applet Registry Admin and
performing a warm boot.
3. After a Clean Boot.
4. After a Firmware Update (see par. 3.11).
Startup stylus calibration on Windows Mobile
When starting the terminal, a Welcome Wizard (with Stylus Calibration) comes up if
valid calibration settings are not available. This happens in the following
circumstances:
1. At the first startup of the terminal.
2. After restoring registry default settings using the applet Registry Admin and
performing a boot.
3. After a Clean Boot.
65