Datalogic Scanning DS6300 Scanner User Manual


 
DS6300
2
2.3.3 Ethernet Connector
This connector is only available for DS6300 Ethernet models and allows the Ethernet
connection between the host and the scanner.
8
1
Figure 39 – Cable RJ45 Male Modular Connector
1
8
Figure 40 – DS6300 RJ45 Female Modular Connector
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT
and IEEE 802.3u 100 BaseTx co
Modu
mpliant.
RJ45 lar Jack Pinout
P in Name Function
1 TX + Transmitted data (+)
2 TX - Transmitted data (-)
3 RX + Received data (+)
6 RX - Received data (-)
4, 5, 7, 8 N.C. Not connected
In order to meet EMC requirements:
use Eth shielded cable
connect the E
thernet interface cable shield to the plant earth ground
NOTE
The cable shield must be connected to the chassis of both connectors.
A ferrite (type Stewart 28A2029-0A0) may also be applied on the scanner
side of the Ethernet cable to reduce electrical noise.