Datalogic Scanning DS6500 Scanner User Manual


 
INSTALLATION
2
Multidata Network
In this layout, one master and up to 7 DS6500 slave readers have their own P.S. and
therefore multiple reading phases. Each P.S. is connected through a C-BOX 100, which in
turn is connected to its relative scanner through a CAB-60XX cable.
The master sends all the individual messages collected from the Lonworks interface as well
as its own to the Local Host through its C-BOX 100.
The following image shows a system consisting of five readers, which are all connected
together using CAB-611X cables and each scanner is individually powered by PG6000
through C-BOX 100.
C-BOX 100
C-BOX 100 C-BOX 100 C-BOX 100 C-BOX 100
Host
P.S.* P.S.* P.S.*
P.S.*
P.S.*
PG6000
PG6000 PG6000 PG6000 PG6000
CAB-611X
CAB-611X CAB-611X CAB-611X
BTK-6000
No-power
No-power No-power No-power
BTK-6000
Master Slave 1 Slave 2 Slave 3 Slave 4
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 59 – Multidata Network
45