Dell 2900 Personal Computer User Manual


 
24 About Your System
E2017 Timer Fail Timer refresh failure. See "Getting Help" on page 147.
E2018 Prog Timer Programmable interval timer
error
See "Getting Help" on page 147.
E2019 Parity Error Parity error. See "Getting Help" on page 147.
E201A SIO Err SIO failure. See "Getting Help" on page 147.
E201B Kybd Controller Keyboard controller failure. See "Getting Help" on page 147.
E201C SMI Init System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 147.
E201D Shutdown Test BIOS shutdown test failure. See "Getting Help" on page 147.
E201E POST Mem Test BIOS POST memory test failure. See "Troubleshooting System
Memory" on page 124. If problem
persists, see "Getting Help" on
page 147.
E201F DRAC Config Dell remote access controller
(DRAC) configuration failure.
Check screen for specific error
messages.
Ensure that DRAC cables and
connectors are properly seated. If
problem persists, see your DRAC
documentation.
E2020 CPU Config CPU configuration failure. Check screen for specific error
messages.
E2021 Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check screen for specific error
messages. See "Troubleshooting
System Memory" on page 124.
E2022 POST Fail General failure after video. Check screen for specific error
messages.
E2110 MBE DIMM ## & ## One of the DIMMs in the set
implicated by "## & ##" has
had a memory multi-bit error
(MBE).
See "Troubleshooting System
Memory" on page 124.
E2111 SBE Log Disable
DIMM ##
The system BIOS has disabled
memory single-bit error (SBE)
logging, and will not resume
logging further SBEs until the
system is rebooted. "##"
represents the DIMM implicated
by the BIOS.
See "Troubleshooting System
Memory" on page 124.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions