Dell DL2200 Computer Drive User Manual


 
28 About Your System
Memory tests
terminated by
keystroke.
POST memory test was
terminated by pressing the
spacebar.
Information only.
MEMTEST lane
failure
detected on
x.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module
Installation Guidelines" on
page 81.
Mirror mode
disabled. For
mirror mode,
DIMMs must be
installed in
pairs. Pairs must
be matched in
size and
geometry.
The memory configuration
does not match the setting in
BIOS. The BIOS setting has
been disabled.
Reconfigure the memory
modules for Memory
Mirroring mode. See
"System Memory" on
page 80.
No boot device
available.
Faulty or missing hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Use a bootable USB key or
hard drive. If the problem
persists, see
"Troubleshooting a USB
Device" on page 130 and
"Troubleshooting a Hard
Drive" on page 139.
See "Using the System Setup
Program and
UEFI Boot Manager" on
page 39 for information on
setting the order of boot
devices.
Message Causes Corrective Actions
book.book Page 28 Wednesday, May 12, 2010 9:26 PM