Dell NSA E8150 Network Router User Manual


 
69 | Safety and Regulatory Information
Safety and Regulatory Information
Safety Instructions
The following conditions are required for proper installation:
The Dell SonicWALL appliance is designed to be mounted in a standard 19-inch
rack mount cabinet.
Use the mounting hardware recommended by the rack manufacturer and ensure
that the rack is adequate for the application.
Ensure that no water or excessive moisture can enter the unit.
Allow unrestricted airflow around the unit and through the vents on the side of
the unit. A minimum of 1 inch (25.44mm) clearance is recommended.
Route cables away from power lines, fluorescent lighting fixtures, and sources
of noise such as radios, transmitters, and broadband amplifiers.
This product is not intended to be installed and used in a home or public area
accessible to the general population. When installed in schools, this equipment
must be installed in a secure location accessible only by trained personnel.
Mount in a location away from direct sunlight and sources of heat. A maximum
ambient temperature of 104º F (40º C) is recommended.
If installed in a closed or multi-rack assembly, the operating ambient temperature
of the rack environment may be greater than the room ambient. Therefore,
consideration should be given to installing the equipment in an environment
compatible with the maximum recommended ambient temperature.
Mount the Dell SonicWALL appliances evenly in the rack in order to prevent a
hazardous condition caused by uneven mechanical loading.
Four mounting screws, compatible with the rack design, must be used and hand-
tightened to ensure secure installation. Choose a mounting location where all
four mounting holes line up with those of the mounting bars of the 19-inch rack
mount cabinet.
A suitably rated and approved branch circuit breaker shall be provided as part of
the building installation. Follow local code when purchasing materials or
components.
Consideration must be given to the connection of the equipment to the supply
circuit. Appropriate consideration of equipment nameplate ratings must be used
when addressing this concern. Do not overload the circuit.
Reliable grounding of rack-mounted equipment must be maintained. Particular
attention must be given to power supply connections other than direct
connections to the branch circuits, such as power strips.
As shipped from the factory this Dell SonicWALL product includes two power
supplies for redundant AC power and added reliability. A field conversion is
available to convert to DC mains.
To disconnect AC power, both power cords must be removed.
The included power cord(s) are approved for use only in specific countries or
regions. Before using a power cord, verify that it is rated and approved for use in
your location.
This model is shipped as AC mains configuration using standard 3 conductor
appliance couplers. A field conversion is available to change to DC mains. The
DC mains connector is a keyed square 6-pin conductor with two blank locations.
To disconnect DC power, an external properly-related disconnect device must
be provided by building or rack installation.
Do not connect AC configured products to DC mains, and do not connect DC
configured products to AC. Detailed instructions are provided with the DC
conversion kit. Product must be configured as all DC or all AC.
DC rating includes tolerances. Do not operate product outside of range shown
on product label.
DC configuration includes input cable with protective earthing conductor (Green
and Yellow wire). This conductor is required to be connected to safety earth
ground of circuit.
Never remove or install a power supply with the AC or DC power cord attached
to the power supply being removed or installed.
Thumbscrews should be tightened with a tool after both installation and
subsequent access to the rear of the product.
Before replacing the fan unit, carefully read and follow the instructions provided
with the unit.
Regulatory Model/Type Product Name
1RK15-08D NSA E8510
Warning—Potential Hazard from Fan