Dell T110 II Server User Manual


 
Dell
PowerEdge T110 II Technical Guide 19
5.4 Environmental Specifications
Table 4 summarizes the environmental specifications for the PowerEdge T110 II.
Environmental Specifications Table 4.
Specification
Operating Requirements
Non-Operating Requirements
Temperature Ranges
(For altitude ≤ 900m or 2952.75ft)
10°C to 35°C
(50°F to 95°F)
-40°C to 65°C
(-40°F to 149°F)
Temperature Ranges
(For altitude > 900m or 2952.75ft)
10°C to T
1
°C
(50°F to T
1
°F)
Temperature Gradient
(maximum per 60 minutes)
10°C
20°C
Humidity Percent Ranges
(noncondensing)
20% to 80%
(maximum wet bulb
temperature = 29°C)
5% to 95%
(maximum wet bulb
temperature = 38°C)
Humidity Gradient
(maximum per 60 minutes)
10%
10%
Altitude Ranges
Low Limits
-50ft
(-15.2m)
-50ft
(-15.2m)
High Limits
10,000ft
(3048m)
35,000ft
(10,668m)
1
Use the formulas in Table 5 to calculate the maximum operating temperature, T (°C or °F), for the given
altitude (in meters or feet).
Formulas for Maximum Operating Temperature at Given Altitude Table 5.
Temperature
Scale
Formula
Altitude in Meters
Altitude in Feet
Celsius
35
Maximum Altitude
(
meters
)
- 900
300
°C
35
Maximum Altitude
(
feet
)
- 2952.75
984.25
°C
Fahrenheit
95
(Maximum Altitude
(
meters
)
- 900) x 1.8
300
°F
95
(Maximum Altitude
(
feet
)
- 2952.75) x 1.8
984.25
°F