Dell
PowerEdge T110 II Technical Guide 35
Factory Configuration
Non Mixed
drives, all
SATA or all
SAS
Configuration
Type
Configuration
Description
Min
HDD
Max
HDD
5
MSTR10CBL
Embedded SATA SW RAID—RAID 10
4
4
SAS/SATA RAID
6a
ASSCBL
Add-in SAS/SATA RAID card, No RAID
(PERC S300) with 1 hard drive
1
1
6b
ASSCBL
Add-in SAS/SATA RAID card, No RAID
(PERC S300) with 2 hard drives
2
2
6c
ASSCBL
Add-in SAS/SATA RAID card, No RAID
(PERC S300) with above 2 hard drives
3
6
7a
ASSR0CBL
Add-in SAS/SATA RAID card, RAID 0
(PERC S300) with 2 hard drives
2
2
7b
ASSR0CBL
Add-in SAS/SATA RAID card, RAID 0
(PERC S300) with above 2 hard drives
3
6
8
ASSR1CBL
Add-in SAS/SATA RAID card, RAID 1
(PERC S300)
2
2
9
ASSR5CBL
Add-in SAS/SATA RAID card, RAID 5
(PERC S300)
3
6
10
ASSR10CBL
Add-in SAS/SATA RAID card, RAID 10
(PERC S300)
4
6
11
ASSCBL
Add-in SAS/SATA RAID card, No RAID
(PERC H200)
1
6
12
ASSR0CBL
Add-in SAS/SATA RAID card, RAID 0
(PERC H200)
2
6
13
ASSR1CBL
Add-in SAS/SATA RAID card, RAID 1
(PERC H200)
2
2
14
ASSR10CBL
Add-in SAS/SATA RAID card, RAID 10
(PERC H200)
4
6
No hard drive
15
NCZCBL
No controller/No hard drive
0
0
Additional restrictions for RAID configurations are as follows:
Configurations 0 to 5 are for 3.5‖ hard drives only
Configurations 6 to 14 are for 2.5‖ or 3.5‖ hard drives (2.5‖ drives available Q2 2011)
12.4 Storage Controllers
T110 II supports software RAID (PERC S100, PERC S300) and hardware RAID (PERC H200) for internal
storage.