Denso BHT-103 Barcode Reader User Manual


 
Terminal Setup
SET PROTOCOLS
<OPTICAL>
1: SERIAL NO. ON OFF
2: H. PARITY ON OFF
3: LINKUP TIME
NONE 30 60 90 120
4: FIELD SPACE
IGNORE DATA
When the settings have been recorded, press Enter. This will return the terminal to the
Set Communication Menu.
SET COMMUNICATION
1: PARAMETER
2: PROTCOL
Press 1 and Enter, and cursor to 115,200.
SET PARAMETER
<OPTICAL>
1: TRANSMIT SPEED
2400 9600 19200
38400 57600 115200
Press
<C> to return to the Set Communication Menu. Press 2: <Connector> and Enter.
SET COMMUNICATION
1: OPTICAL
2: CONNECTOR
3: COM PORT
4: PROTOCOL TYPE
Press 1 or move cursor to the
<Serial No.> field and move cursor to <On>.
Press 2:
<H. Parity> and move cursor to <On>.
Press 3: <Linkup Time> and move cursor to <30>.
Press 4: <Field Space> and move cursor to <Ignore>.
SET PROTOCOL
<CONNECTOR>
1: SERIAL NO. ON OFF
2: H. PARITY ON OFF
3: LINKUP TIME
NONE 30 60 90 120
4: FIELD SPACE
IGNORE DATA
Supported Equipment Manual March, 2006
2-10