If an error occurs during uploading
If some error occurs during uploading, one of the following screens will appear and
the beeper beeps three times.
To retry the uploading operation, press the 1 and ENT keys; to abort it, press the 2
and ENT keys.
Press the C key to return to the SYSTEM PARAMETER transfer menu.
Problem
The memory is insufficient for setting up the BHT
system parameter file to be uploaded.
Solution
Press the C key to return to the SYSTEM MENU,
then delete unnecessary files in the memory. (Re-
fer to Subsection 2.5.3, [ 9 ].
Problem
The memory has already contained 80 files, so the
BHT system parameter file cannot be set up.
Solution
Press the C key to return to the SYSTEM MENU,
then delete unnecessary files in the memory. (Re-
fer to Subsection 2.5.3, [ 9 ].
Problem
Uploading has failed.
Solution
To retry uploading, press the 1 key.
To return to the SYSTEM MENU, press the 2 key.
Check the interface port, communications param-
eters, and communications protocol type in the
SET SYSTEM menu or perform the communica-
tions test in the TEST menu. (Refer to Subsection
2.5.3, [4.5] and [5.5].)
It is also necessary to check the communications
parameters setup of the host computer.
UPLOAD
Out of memory!!
UPLOAD
Too many files!!
UPLOAD
__BHT.SYS
Communication error!!
Retry?
1:Yes 2:No