Digi X2 Network Router User Manual


 
129
Configure Digi devices
Test only when idle: if no data is received for the above period of time:
Specifies that the test repeat interval (above) is to be used as an idle period
interval. That is, initiate the selected link integrity test only after no data has
been received for the specified interval of time. This changes the behavior of
the test in that the test interval varies according to the presence of other data
received from the mobile connection.
Although using this idle option may result in less data being exchanged over
the mobile connection, it also prevents the link integrity tests from running as
often to verify the true bi-directional state of that connection.
Reset the link after the following number of consecutive link integrity test
failures: Specifies that after the configured number of consecutive link
integrity test failures, the mobile connection should be disconnected and
reestablished. This value must be between 1 and 255. The default is 3. When
the mobile connection is reestablished, the “consecutive failures” counter is
reset to zero.
If the mobile connection is disconnected for any reason (including not as a
result of a link integrity test failure), the consecutive failures count is reset to
zero when the mobile connection is reestablished.
Status and statistical information for mobile connections
Once the mobile settings have been configured, you can monitor the status of mobile
connections by going to Administration > System Information > Mobile. See "Mobile
information and statistics" on page 184.
From the command line, this mobile information is displayed by issuing display mobile
and display pppstats commands.