DGS-3100 Series Firmware Release Notes
12
on the ports configured by the Web (without a trap)
6 When user tries to show VLAN, STP and GVRP information via CLI, the ‘q’
button doesn’t interrupt the displaying when type it.
7 The QoS is not working properly when using queue 3 across the stack. It
happens in strict priority and also in WRR, if the user does not use queue
3, everything is working fine.
8 A fatal error happened when there are multiple HTTP connections sending
large files at the same time (DI20080627000006).
9 Sometimes when rebooting the Master or Backup Master switch in a
stack, the stacking may crash (DI20081106000013).
10 When configuring the ACL function with more than 100 access IDs, the
system will display a warning message “Exceeded the maximum ACE
allowed in the system”. However, the ACL rules are not running out
actually (DI20081028000024).
11 When users try to login the Web UI with ‘user’ privilege, the system will
display an “Invalid username or password” error message
(DI20080630000017).
12 When a client sends an IGMP leave request to one multicast group,
another group for that user will be disconnected, too
(DI20081001000004).
13 When users configure MSTP feature, MSTP can not be configured for
non-existing VLAN (DI20080820000010).
14 Fix the problem of incorrect statistics number of Port Utilization
(DI20080807000011).
15 When users connect several clients on several Slave switches and also
enable flow control. If clients overload the stacking bandwidth to Master
switch, the stacking may break and all switches will reboot to re-build the
stacking.
16 When executing “show port” command in a single switch,
DGS-3100 will always display the maximum interfaces (48 ports
multiply with six switches in a stack).
v2.00.47
1
In current design, the ACL was port
based and only support 128
access rules for whole system ( though in spec we stated 240
rules support and each rule is system-based )
For example, if you configure one ACL in stacking mode and apply
it to more than 128 ports, you'll have problem for this function.
With firmware version 2.00.47, if user applies a rule for the whole
stacking, it will only be counted as 1 rule. For the detail of new
ACL mechanism, please refer to the session, “Notes about ACLs
capacity in the DGS-3100 Series”, in user manual.
2 Current system IP only supports classful IP address, such as class
A, B or C with associate subnet mask such as /8, /16 or /24, if you
configure Class C IP address with wrong subnet mask, say
/16(255.255.0.0), you will receive an error message saying that
the mask is illegal.
3 When user configures ACL to change the 802.1p packet priority,
the system will not map the packet to the right queue.