Handle
When lamp time exceeds 1000 hours:
When the accumulated lamp time reaches 1000, a message
indicating “1000 h” will appear on the projected screen.
* Press any key to delete the message.
When lamp time exceeds 1900 hours:
When the accumulated lamp time reaches 1900 hours:
The LAMP indicator on the projector lights up.
When the accumulated lamp time exceeds 1900 hours:
“Lamp replacement” appears on the screen.
* Press any button to delete the message.
Replacing the Lamp
The light source lamp and its lamp time
The light-source lamp has a service life. The life of lamps currently used for this projector is about 2000 hours.
[Average lamp life: 2000 hours]
When the light-source lamp approaches the end of its service life, deterioration progresses rapidly. Please install a new lamp when
the accumulated lamp time exceeds 1900 hours or at least get a replacement lamp ready. Depending on the operating conditions,
the lamp may have to be changed earlier. If the image remains dark or the tone, unusual, even after adjustment, please replace the
lamp as soon as possible. You can check the accumulated used hours of the lamp via the “Lamp Time” item in the “Information”
menu. ( page 40)
Please purchase the new lamp unit from the authorized dealer where you purchased the projector.
Exchange lamp Part No.: BHL5006-S
The procedure for lamp replacement
1.
Loosen the screws and detach the light-source lamp cover.
Loosen the two screws with a ª screwdriver.
2.
Loosen the screws and lift up the handle.
Loosen the two screws with a ª screwdriver.
When the lamp time exceeds 2000 hours:
The lamp indicator on the projector blinks.
“Warning” and “Lamp replacement” appear on the screen;
the word “Warning” blinks.
To cancel the message, press the EXIT button.
However, the same message will appear again every one-
hour.
Once the lamp time exceeds 2000 hours, and the projec
tor is either put into the standby state or turned off, projec
tion will not be possible again until the lamp is replaced
and the “Lamp time” is reset. ( page 45)
When the lamp time exceeds 2010 hours:
The projector quits and shuts down.
The LAMP and OPERATE indicators blink on the projector.
The projector does not turn on unless the lamp (lamp unit)
is replaced and the “Lamp time” is reset. ( page 45)
About lamp replacement
If the projector is set in a constricted place, attempting to replace the lamp in that place could cause injury. Move the projector
to a place large enough to work in.
To avoid malfunctions, be sure to use only genuine replacement parts. Also, never attempt to re-use an old lamp as this could
cause marked performance deterioration or lamp blow-out leading to projector malfunction. In the worse case, broken pieces
of glass from the lamp may cause injuries.
Do not replace the lamp immediately after the projector has been used. The temperature of the lamp unit is still high and
could cause a burn. Allow a cooling period of one hour or more before replacement.
Before starting to replace the lamp, disconnect the power cord from the wall outlet while the STAND BY indicator is on.
Replacing a lamp while the power cord is connected could cause injury or electric shocks.