Dukane 28A9017 Projector User Manual


 
45
QUICK ALIGN.
PC VIDEO
VOLUME
PRESET HIDE
ENTER
MENU EXIT
FREEZE
OPERATE
V-KEYSTONE H-KEYSTONE
SCREEN
DIGITAL
ZOOM
FOCUS
W
S
PRESET HIDE
EXIT
press for
2 seconds
EXIT
PRESET
HIDE
VOL( )
Press as per normal
Press for 2 seconds or more
Replacing the Lamp
1.
Insert the main plug. The projector will go into the stand
by mode.
ON: STAND BY indicator lights up.
2.
Press the EXIT, HIDE, PRESET buttons on the remote
control sequentially, then press VOL ª for 2 seconds or
more.
The STAND BY and OPERATE indicators alternately blink about
every approx.3 seconds. After blinking stops, “Lamp time” resets
and the projector returns to the stand-by state (STAND BY indicator
lights up).
Resetting the lamp time
After installing a new lamp, reset the “Lamp time” counter inside the projector.
When this is done, a new count will start.
If the display of the accumulated lamp time has reached 2000 hours, the projector will not work (lamp does not light up) unless the
lamp time is reset.
To ensure the lamp time has been reset.
The Lamp time can be checked via the “Lamp time” item in the “Infor-
mation” menu. ( page 32, 33, 34, 40)
Caution for reset work
Reset the “Lamp time” only when you have replaced the lamp.
Never reset it while the lamp is still in use, otherwise the approxi-
mate standard for gauging replacement time may be inaccurate, lamp
performance may suffer and lamp blow-out may also occur.