Dukane 403-573-02 Power Supply User Manual


 
Page  20 
iQ Series, Auto User’s Manual
Dukane Manual Part No. 403-573-02
Optional MPC Interface Connections
Complete the same basic connections used for the stan-
dard iQ Auto conguration as previously described.
AC Line Input
System Control Inputs/Status Outputs
Ultrasound Output
Grounding (optional)
In addition to completing Steps 1- 4 of the basic con-
nections as previously described, complete Steps 5 and
6 to wire the MPC Control Inputs/Status Outputs as
described below.
Figure 3-2 Generator Front View - Optional MPC Model
Optional Multi- Probe Control
(MPC) Interface Model
The iQ Auto MPC model includes an optional MPC
Interface circuit board that powers and controls an external
MPC multi- probe control module. This external module,
(that can be ordered with a minimum of two probe controls
up to a maximum of 16 probe controls), must be purchased
in addition to generator Model 40AT060-2N-MO (iQ Auto
with MPC option) for a fully functional MPC system.
The connections needed for the MPC Interface board are
described below. Connections required for the external
MPC module are also described below.
Details about the various system connectors and their
pin assignments are covered in the next section.
Step 5. MPC I/O - Wire the MPC control/input signals
and status output signals terminal block to the
user-supplied automation control system - E
in Figure 3-2.
Step 6. MPC INTERFACE - Attach one end of the MPC
Interface cable (Dukane # 200-1408-XX) to the
MPC Interface connector on the iQ Auto panel
-F in Figure 3-2. Connect the other end of the
cable to the MPC INTERFACE connector on
the right rear of the MPC module.
NOTE
The MPC Interface cable is a separate line
item on the iQ Auto system order. The -XX
at the end of the cable number species
cable length. This will vary depending on
your MPC installation.
POWER INLET
CONTROL
CONNECTOR
U/S CONNECTOR
U/S
SYSTEM I/O
OPTIONAL MPC
CONNECTORS
POWER
STATUS (LED)
MPC I/O
MPC INTERFACE
GROUNDING STUD
AMPLITUDE
20%
100%
AMPLITUDE
ADJUSTMENT
CONTROL
See NOTE
on Page 22.
NOTE
Amplitude adjustment will affect ALL
MPC points.