Section 3 – Installation
Dukane Manual Part No. 403-573-02
MPC Module Status LEDs
System Status
The front panel SYSTEM STATUS LED lights up
GREEN when the system is powered and ready - E
in Figure 3-6.
If this LED is lit with a YELLOW/ORANGE color, a
recoverable fault condition has tripped. This indicates
that the system is operational, but a fault condition has
occurred preventing normal operation. Examples of this
type of fault would be a generator overload that will
automatically reset when the next weld cycle begins,
or the automation control system is selecting a channel
that doesn’t exist - trying to select channel 10 for an 8
channel system, for instance.
If this LED lights up RED, a hardware fault has been
sensed, and the unit should be returned to Dukane for
servicing.
Probe Selection Status
The PROBE SELECTION STATUS LED - F in
Figure 3-6 - lights up GREEN indicating it is the
selected probe.
A probe’s LED turns to RED (from GREEN) when
ultrasonic power is activated.
F
E
Figure 3-6 MPC Module Status LED’s
NOTE
Refer to Section 4, System Opera-
tion, for more information.