Dukane 403-573-02 Power Supply User Manual


 
Page  23
Section 3 – Installation
Dukane Manual Part No. 403-573-02
MPC Module Installation
Guide
MPC modules are designed for assembly systems where
one ultrasonic generator is sequenced to as many as 16
ultrasonic probes.
The MPC module is typically supplied as a stand-alone
bench-top unit, or as a component that can be mounted in
a through-panel conguration.
No special installation is needed for a stand-alone MPC
module that can be put on a bench top or a shelf.
Use the following installation recommendations for a
panel mounted MPC module.
A
C
C/2
D
0.25
[06.35]
(6 PLCS)
MPC0404
7.12 1.75 6.75 2.25
[181 mm]
MODEL "A" "B" "C" "D"
[45 mm] [171.5 mm] [57.2 mm]
MPC0808
10.88 1.75 10.50 2.25
[277 mm] [45 mm] [266.7 mm] [57.2 mm]
MPC1616
18.25 1.75 18.00 2.25
[464 mm] [45 mm] [457.2 mm] [57.2 mm]
Cut Outs
For panel mounted modules:
Use Figure 3-3 below to determine the size of the cut
needed for your equipment panel.
Make the appropriate cut, and install the MPC module
securing the mounting ange to the equipment panel
before continuing with the cable connections.
Figure 3-3 MPC Module Cutout Guide