Page 44
iQ Series, Auto User’s Manual
Dukane Manual Part No. 403-573-02
iQ Auto
(same as above)
Input Common
U/S Activate
Fault Reset
Ground
+DC
NPN (Sinking) Type Input Circuit
Input Voltage Range DC 24V 10%
Input Current 10mA(typ) @ DC 24V input
System I/O Connector
(Pin 13)
(Pin 12)
(Pin 11)
±
Figure 6-2 NPN Type Input Circuit