NOTE
Ultrasound Output Connector
The ultrasound output connector
used with all standard generators is
a high voltage (5000V) coaxial style
SHV-BNC connector. This connector
provides superior shielding of electri-
cal noise, compared to other types
of connectors. The ultrasound output
connector mates with fully shielded
coaxial ultrasound cables that are
secured with a simple and reliable
quarter-turn bayonet style attachment
mechanism.
The ultrasonic output from this con-
nector (that drives the attached
ultrasonic load) is a very high AC volt-
age (1200VAC). At high power levels
this can exceed 2 amps of current and
must be securely terminated via the
ultrasound cable for safe operation.
Use original equipment ultrasound
cables for safe and reliable system
operation. Improperly assembled
ultrasound cables can result in high
voltage arcing and will destroy the
ultrasound connectors.
MPC Probe Control
When the optional MPC Interface and MPC I/O
connectors are used, the generator has the capability of
controlling as many as sixteen compatible probes. One
probe can be turned on at a time while the sequence
of probe activation is determined by the user’s
automation.
The table below shows how the setup bit inputs
correspond to the probes.
MPC Probe
Selected
3 2 1 0
Off Off Off Off 1
Off Off Off On 2
Off Off On Off 3
Off Off On On 4
Off On Off Off 5
Off On Off On 6
Off On On Off 7
Off On On On 8
On Off Off Off 9
On Off Off On 10
On Off On Off 11
On Off On On 12
On On Off Off 13
On On Off On 14
On On On Off 15
On On On On 16
Table 3-III MPC Setup Bit Inputs