Page 30
iQ Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-583-00
Navigating the Modes
When the generator is rst powered up, the default
operating mode is Automation, and Automation Weld
is shown at the top of the display as shown in Figure 5-1.
Navigate to Time Mode
1. Follow the sequence shown in the gures to the right
to navigate from Automation mode to Time mode.
In Automation mode, press the TIME key
(Figure 5-2).
2. The phrase, Enter Changes Mode, means when the
ENTER key is pressed, the mode will change. So
press the ENTER key, and the Weld by Time screen
seen in Figure 5-3 appears.
3. Set the time.
Use the and the keys to move the cursor
and to set the digits for the weld time you want.
4. Press the ENTER key to accept the time that has
been set (Figure 5-4).
Press the CANCEL key if you decide not to set the
time.
NOTE
Navigating to Automation Mode
Set Time or Energy (depending on mode) to
OFF, and press ENTER.
This will put you back in Automation mode.
Alternately:
Find an empty setup. Press SETUP.
Press ENTER.
A pop-up screen about defaults appears.
Select YES to load the default operating mode
which is Automation, and you can weld using
the Automation mode.
+ -
Automation Weld
Weld Time 0.000 S
Weld Energy 0 J
# 2
Figure 5-1 Automation Weld Mode
TIME key
Automation Weld
Weld By Time
OFF
Enter Changes Mode
ENTER key
Figure 5-2 Navigate to Time Mode
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Weld By Time
OFF
S
Figure 5-3 Time Weld Mode - 1
Weld by Time
Press Enter To Accept
Press Cancel To Abort
Weld Time
0.500 S
Figure 5-4 Time Weld Mode - 2
ENTER key
Set the time.
Setup #1Empty
Load Defaults?
YES NO