iQ Series, Ultrasonic Hand Held Systems User’s Manual
Dukane Manual Part No. 403-583-00
Hold
HOLD is used more often with Time or Energy modes, but
it can be used with the Automation mode.
HOLD does not allow the automation program to begin a
new cycle until HOLD is nished.
To set a HOLD period:
1. Select the weld mode (Automation, Time, Energy).
2. Set the time and energy parameters as needed.
3. Press the HOLD key. The screen will appear as it
does in Figure 5-9.
4. Set the time with the
+ -
keys.
(A maximum of 5.0 seconds.)
Figure 5-9A shows a setting for 2.0 seconds.
5. Press the ENTER key to conrm your selection.
Amplitude Adjustment
Amplitude refers to the movement of the horn at its
workface. The higher the amplitude setting, the higher the
power output level will be at a particular pressure level.
Amplitude settings are given as a percent of the horn’s
nominal amplitude in the range of 20% to 100%.
It is typical to leave the amplitude setting at 100% for
maximum power output.
To adjust amplitude:
1. Press the AMP key. The screen will appear as in
Figure 5-10.
2. Set the amplitude level using the keys and the
+ -
keys.
3. Press ENTER to conrm your amplitude setting.
Hold Time
OFF S
Figure 5-9 HOLD Time - 1
Amplitude
100 %
Figure 5-10 Amplitude
Hold Time
2.0 S
Figure 5-9A HOLD Time - 2