2.3.2 Power Requirements
The RTM has a typical power dissipation of 22W, and a maximum power dissipation of 30W.
Table 2-1 Environmental Requirements
Requirement Operating Non-Operating
Temperature 0ºC to +40ºC (normal operation) according
to NEBS Standard GR-63-CORE
0ºC to +55ºC (exceptional operation)
according to NEBS Standard GR-63-CORE
-40ºC to +85ºC
Temp. Change +/- 0.25ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.25ºC/min
Rel. Humidity 5% to 95% non-condensing according to
Emerson-internal environmental
requirements
5% to 95% non-condensing
according to Emerson-internal
environmental requirements
Vibration 0.1g from 5 to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute
5-20 Hz @ 0.01 g
2
/Hz
20-200 Hz @ -3.0 dB/octave
Random 5-20 Hz @ 1 m
2
/Sec
3
Random 20-200 Hz @ -3 m/Sec
2
Shock Half-sine, 11 m/Sec, 30mSec/sec
2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec
2
Free Fall 1,200 mm/all edges and corners
1.0m (Packaged) per ETSI 300
019-2-2 (Blade level packaging)
100mm (unpackaged) per GR-63-
CORE