Emerson SS-100 Server User Manual


 
SS-100 Serial Server Installing the SS-100 • 1
1 Installing the SS-100
The CPC SS-100 Serial Server (P/N 570-
2000) is a device that allows Retail Solutions
REFLECS controllers (RMCC, BEC, or
BCU) to communicate over a TCP/IP Ethernet
network using the controller’s serial port. Tra-
ditionally, REFLECS controllers have relied
on a modem or a serial cable connection. With
an SS-100 installed, the REFLECS can be in-
tegrated with a company’s existing LAN or
WAN.
A kit is included with the SS-100, which
consists of:
5V power supply
9-pin (DB9) to 9-pin connector
9-pin to 25-pin (DB25) connector (STC)
10’ DB9 serial cable
535-1190 DB9 computer to REFLECS controller
laptop cable (UltraSite connection only)
DB25 null modem adapter (HALComm connection
only)
DB9 female/female STC gender changer (HAL-
Comm connection only)
1.1. Working with the Network
Administrator
Like other computers on the network to which it is at-
tached, the SS-100 is also a network node. Because of this,
it is important to work with the network administrator.
Without the cooperation of the network administrator, it
will be difficult to make the SS-100 function properly.
1.2. IP Address Specification
An IP address and subnet mask are denoted as a series
of four decimal numbers separated with periods. Each
number has a value between 0 and 255.
The following are examples of valid IP addresses and
subnet masks. The actual numbers used as IP addresses
must be determined by the network administrator.
IP Address 192.168.1.33
Subnet Mask 255.255.255.0
“Empty” IP Address 0.0.0.0
1.3. Network Considerations
Like any other node on the network, the SS-
100 must be assigned an IP address. For this rea-
son, the network administrator’s input is required
for the SS-100 installation. Obtain the following
information from the network administrator be-
fore configuring the SS-100.
SS-100 IP address (required)
Subnet mask (required)
Primary DNS IP address (may not be re-
quired)
Secondary DNS IP address (may not be re-
quired)
Primary gateway IP address (may not be required)
Secondary gateway IP address (may not be required)
1.4. Ethernet Network Wiring and
Wire Types
To connect the SS-100 to an existing Ethernet network,
use the same standard Category 5 network cable used by
the rest of the Ethernet network. If the SS-100 is being
wired as part of a brand new network installation, consult
your network administrator or IS technician for the proper
wire type.
In either case, you will need to crimp an RJ45 connector
to the end of the network cable segment that will connect to
the SS-100.
2 SS-100 Wiring
Requirements
Required Equipment:
110VAC/5VDC power transformer
DB25/DB9 straight through connector (STC)
535-1190 DB9 computer to REFLECS controller
laptop cable (UltraSite connection only)
DB25 null modem adapter (HALComm connection
only)
DB9 female/female STC gender changer (HAL-
Comm connection only)
Installation Guide
RJ45 connection to a TCP/IP Network (not provid-