Configuration Guidelines
2-2 Installation Requirements and Guidelines
Configuration Guidelines
TheNACControllerPEPsfortheEnterasys NAC Controllerareequippedwithafirmwarebased
managementtool,whichprovidesthecapabilitytoconfiguretheNACControllerPEPandaccess
chassis,powersupply,andfaninformation.
LANVIEW LEDs
ThefollowingsectionsdescribetheLANVIEWLEDindicationsforthefollowing:
Enterasys NAC Controllerpowersupplies
Enterasys NAC Controllerfans
Power Supply LEDs
TherearetwopowersupplyLEDsonthefrontpanelofthechassis,oneforeachpowersupply.
RefertoFigure 21forthelocationofthepowersupplyLEDs.Table 21describesthedifferent
statesofthepowersupplyLEDsunderdifferentconditions.
Figure 2-1 Power Supply LEDs
1 PS1 LED 2 PS2 LED
Table 2-1 Power Supply (PS) LED Status Definitions
Condition PS1 PS2 PS1 LED PS2 LED
1 ON ON Green Green
2 ON OFF Green Red
3OFFONRed Green