ESC p
E
XECUTING
COMMAND
[Name]
Generate pulse
[Format]
ASCII ESC p
m t1 t2
Hex 1B 70
m t1 t2
Decimal 27 112
m t1 t2
[Range]
m
= 0, 1, 48, 49
0
t1
255
0
t2
255
[Default]
None
[Description]
Outputs the pulse specified by
t1
and
t2
to connector pin
m
as follows:
[Notes] The pulse ON time is [
t1
× 2] ms, and the OFF time is [
t2
× 2] ms.
When
t2
<
t1
, the printer processes
t1
× 2 ms as the OFF time.
m
Function
0, 48 Drawer kick-out connector pin 2
1, 49 Drawer kick-out connector pin 5
Program Example
PRINT #1, CHR$(&H1B);"p";CHR$(0);CHR$(25);CHR$(250);