Extreme Networks Px Series Switch User Manual


 
Px Series Application Switch Installation and Configuration Guide 10-5
Showing Configuration Details
Status Displays
The show health and show server details commands display similar (but not
identical) information. The following examples illustrate the output from these
commands (for the configuration shown in the example on page 10-4).
* SummitPx1:26 # show health
Healthcheck is currently enabled
default interval 30 sec, retry interval 10 sec, arp interval 5 min
default fail after 2, restore after 2
15/15 ping rx/tx
4 UP 4 *UP
flags: E - check Enabled, D - check Disabled, R - mac is resolved
ra - restore after, fa - fail after, left - secs till next check
* SummitPx1:28 # show server details
flags: E - check Enabled, D - down, U - Up, R - mac is resolved,
N - mac is not resolved, F - forced down
run - '>' than or '<' than 0, number of consecutive passed or failed
respectively
ra - restore after, fa - fail after, left - secs till next check
index IP port proto state check left run ra fa ups flg
1 10.65.8.50 ICMP UP IDLE 2 2 2 2 2 RE
1 0.65.8.50 8080 ICMP *UP IDLE 6 0 2 2 0 RE
2 10.65.8.51 ICMP UP IDLE 33 2 2 2 2 RE
2 10.65.8.51 8080 ICMP *UP IDLE 16 0 2 2 0 RE
40 10.65.8.52 ICMP UP IDLE 19 2 2 2 2 RE
40 10.65.8.52 80 ICMP *UP IDLE 39 0 2 2 0 RE
41 10.65.8.53 ICMP UP IDLE 16 2 2 2 2 RE
41 10.65.8.53 80 ICMP *UP IDLE 7 0 2 2 0 RE
index IP port proto flg curr-conns max-connections run ra fa
1 10.65.8.50 ICMP URE 0 10000 2 2 2
1 10.65.8.50 8080 ICMP RE 0 2 2
2 10.65.8.51 ICMP URE 0 10000 2 2 2
2 10.65.8.51 8080 ICMP RE 0 2 2
40 10.65.8.52 ICMP URE 0 10000 2 2 2
40 10.65.8.52 80 ICMP RE 0 2 2
41 10.65.8.53 ICMP URE 0 10000 2 2 2
41 10.65.8.53 80 ICMP RE 0 2 2