Extron electronic DTPTMK232 Network Router User Manual


 
DTP T EU 332, DTP T EU 232, DTP T MK 332, and DTP T MK 232 • Installation and Operation 14
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances
up to 330 feet (100 meters) (DTP T EU 332 and DTP T MK 332) or 230 feet (70 meters)
(DTP T EU 232 and DTP T MK 232) and reduce transmission errors.
Use the following Extron XTP DTP 24 STP cables and DTP 24 connectors for the best
performance:
XTP DTP 24/1000 Non-Plenum 1000’ (305 meters) spool 22-236-03
XTP DTP 24P/1000 Plenum 1000’ (305 meters) spool 22-235-03
XTP DTP 24 Plug Package of 10 101-005-02
If not using XTP DTP 24 cable, at a minimum, Extron recommends 24 AWG, solid
conductor, STP cable with a minimum bandwidth of 400 MHz.
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.
Use no more than two pass-through points, which may include patch points, punch
down connectors, couplers, and power injectors. If these pass-through points are
required, use CAT 6 or 6a shielded couplers and punch down connectors.
NOTE: When using STP cable in bundles or conduits, consider the following:
Do not exceed 40% fill capacity in conduits.
Do not comb the cable for the first 20 meters, where cables are straightened,
aligned, and secured in tight bundles.
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.
Separate twisted pair cables from AC power cables.
IR and RS-232 Connector Wiring
Figure 12 shows how to wire the Remote RS-232 and Over DTP RS-232 and IR
connectors.
RxTx
TxRx
Gnd
Gnd
IR Device
RS-232 Device
Tx Rx G
RS-232
REMOTE
Tx Rx GTxRx
RS-232
OVER TP
IR
Figure 12. IR and RS-232 Connectors Wiring
NOTES:
The IR Tx and Rx line pair and the RS-232 Tx and Rx line pairs must each cross
once between their connectors and the source or destination.
The length and preparation of exposed wires is important (see the second and third
power connector CAUTIONS on the next page for details).