Extron electronic IN1508 Switch User Manual


 
3-43IN1508 Scaling Presentation Switcher • Operation
Problem Possible cause Solution
Total pixels setting Active pixels setting Select Picture>Advanced>Active
cannot be increased. may be too low. Pixels and increase the setting to
match the input signal.
Horizontal start Select Picture>Advanced>H
may be too high. Start and reduce the setting to
match the input signal.
Output resolution may Press the front panel Output Rate
be too low. button to select a setting that is
greater than or equal to the active
area.
Active lines setting Vertical start Select Picture>Advanced>
cannot be increased. may be too high. V Start and reduce the setting to
match the input signal.
Output resolution may Press the front panel Output Rate
be too low. button to select a setting that is
greater than or equal to the active
area.
Horizontal start Total pixels setting Select Picture>Advanced>Total
setting cannot be may be too low. Pixels and increase the setting to
increased. match the input signal.
Active pixels setting Select Picture>Advanced>Active
may be too high. Pixels and reduce the setting to
match the input signal.
Vertical start. Active lines setting Select Picture>Advanced>Active
may be too high. Lines and reduce the setting to
match the input signal.