Extron electronic MLA-VC10 Power Supply User Manual


 
MLA-VC10 • Installation and Setup
MLA-VC10 • Installation and Setup
Installation and Setup, cont’d
2-112-10
Connecting an MLA-VC10
to an external power supply
AB
MLA-VC10
front panel
MLC/RS-232
Power port
Ground ( )
+12VDC input
MLC/RS-232
POWER
Ground all devices
An external
power supply
(12VDC, 1A max.)
White or
white-striped
wire
To avoid introducing noise and static into the audio
channels, the MediaLink Controller (if used), the power
supply, the MLA-VC10, and the amplifier or mixer
should all share the same grounding source.
The 12VDC, 1 amp power supply kit (part #70-055-01)
is not included with the MLA-VC10.
Wiring the Amp/Mixer Control connector
The illustration below shows how to wire the 3.5 mm, 2-pole
captive screw connector for controlling the amplifier or mixer.
AMP/MIXER
CONTROL
CTRL
Ground ( )
To Amplifier
0VDC to +10VDC
*
*
The actual maximum control voltage depends on the
Configuration DIP switch settings, but the maximum
power output will not be reached if the amplifier's
control port voltage measures more than 10VDC.
6 feet (1.8 m) maximum
between the MLA-VC10
and the amplifier
Wiring the MLA’s Amp/Mixer Control connector
In some applications the amplifier’s front panel volume
control knob may be disabled when the MLA is attached
to the amplifier’s control port.
See the illustration on page 2-9 for power wiring instructions.
The Configuration DIP switches must also be set to select the
outgoing voltage. See pages 2-7 to 2-9.
Wiring the MLC/Power connector
The 12VDC, 1 amp power supply kit (part #70-055-01)
is not included with the MLA-VC10.
AB
MLA-VC10
Front Panel
12VDC
Power Supply
Connecting an MLA-VC10 to an MLC 206
Connecting an MLA-VC10
to a Computer or Third Party Control's RS-232 Port
MLA-VC10's
front panel
MLC/RS-232
Power port
NOTE
The external power
supply provides power
to both the MLA-VC10
and the MLC.
MLC 206's
MLS/Power
port
+12VDC
Ground ( )
NOTE If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
AB
MLA-VC10
Front Panel
12VDC
Power Supply
MLA-VC10's
front panel
MLC/RS-232
Power port
+12VDC
Ground ( )
NOTE If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
NOTE
Use the MediaLink control software to set the MLC’s volume control to “Switcher”
instead of “Projector”. Refer to the MediaLink Controllers User’s Manual.
MLC/RS-232
POWER
MLC/RS-232
POWER
ABCDEABC
IR
Display/Source Control
Extron Switcher Control
Relays IR /RCM
RS-232
DE ABC ABD
1A 1B2A2B3A3B
123456
Tally Out
MLS
/Power
33-644-01 A
07 01
Printed in the
USA
Ground ( )
+12VDC
Transmit (Tx)
B
Receive (Rx)
A
Transmit (Tx)
B
Receive (Rx)
A
AB
MLS
/
Power
Computer or
Third Party Control's
RS-232 Port
Transmit (Tx)
Receive (Rx)
+12VDC
Ground ( )
B
A
MLC 206 Bottom Panel
Rx Tx Gnd
Transmit (Tx)
Receive (Rx)
B
A
Computer or
Third Party
Control's
RS-232 Port
Ground ( ) Ground ( )
Ground all devices
White or
white-striped
wire
An external
power supply
(12VDC, 1A max.)
MLA-VC10
POWER/
STATUS
A B
MLC/POWER
Ground all devices
An external
power supply
(12VDC, 1A max.)
MLA-VC10
POWER/
STATUS
A B
MLC/POWER
White or
white-striped
wire