MLA-VC10 • Specifications, Part Numbers, and Accessories
MLA-VC10 • Specifications, Part Numbers, and Accessories
Specifications, Part Numbers, and Accessories
A-2
Specifications
Control — amplifier
Maximum voltage output .......... 10VDC ± 5%
General
Power............................................. 12VDC from a 1 A external power supply
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) /
10% to 90%, non-condensing
Operating +32° to +122°F (0° to +50°C) /
10% to 90%, non-condensing
Rack mount................................... No
Enclosure type.............................. Plastic
Enclosure dimensions ................. 1.0" H x 2.4" W x 2.3" D
2.5 cm H x 6.1 cm W x 5.8 cm D
Product weight............................. 0.2 lbs (0.1 kg)
Shipping weight ........................... 1 lb (0.5 kg)
Vibration ....................................... ISTA/NSTA 1A in carton
(International Safe Transit Association)
Listings .......................................... UL, CUL
Compliances ................................. CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor
Specifications are subject to change without notice.
Included Parts
These items are included in each order for an MLA-VC10:
Included parts Part number
MLA-VC10 60-502-01
3.8 mm, 2-pole captive screw connector 10-319-15
3.5 mm, 5-pole captive screw connector 10-319-10
MLA-VC10 user’s manual 68-690-01
Cables
Plenum Comm-link cable Part number
50 feet, 100 feet, 200 feet 26-461-01, -02, -03
300 feet, 400 feet 26-461-05, -04
A-3
MLA-VC10 Functional Block Diagram
MLA-VC10
Control
Voltage
High Z
Amp/Mixer
+V
Microcontroller
Relay
DIP Sw.
Digital
Pot.
Digital
Pot.
Low Z
RS-232/MLC Control
Sets Max Voltage
Tx Rx Gnd+12V
DC Voltage Controller
Power Up Amp
Protection
- Amp/Mixer must support remote volume capabilities.
- Output impedance of MLA-VC10 is lower than the input impedance of the Amp/ Mixer.
- DIP switches set maximum control voltage (10VDC max.).
- Relay shorts to ground when power is removed and for 5 seconds after power up.