Fujitsu fi-4990C Scanner User Manual


 
6-53
7. Press
ENTER
.
The PAPER SIZE screen appears with the
current setting A4P blinking (blinking indicates
“changeable”).
8. Press or .
The displayed parameter changes (LTP, B5P,
A5P, A4L, etc.).
9. When the desired parameter appears, press
ENTER
to save the change.
The parameter set screen appears with the new
parameter blinking.
10. Press
CANCEL
The scanning parameters screen appears with
the new parameter replaced and with SETUP
blinking (blinking indicates “selectable”).
11. Press .
START blinks (blinking indicates “selectable”).
12. Press
ENTER
.
The scanner feeds and scans documents
continuously until it detects an error (usually
“Hopper empty”). During feeding, the upper line
indicates “Feeding!!” and the lower line indicates
the number of sheets fed.
To halt the test, press
CANCEL
.
To restart the test, press
ENTER
.
To restart from a hopper empty status, put
sheets of paper on the hopper table and press
CANCEL
.
To quit the offline feed test, press
CANCEL
in
the halted state.
13. To quit the <<TEST MODE>>, turn off the power.
PAPER SIZE
A4P
PAPER SIZE
LTP
S LTP 200 LA
LA
S LTP 200 LA
START SETUP
S A4P 200 LA
START SETUP
Feeding!!
12345678 1234
15C6.P65 01.2.17, 5:47 PM53