5. Close the ADF.
You should hear the ADF click when it returns to its
original position.
6. Turn on the scanner.
ScanSnap Manager icon changes from to .
7. Right-click the "ScanSnap Manager" icon on the
task bar, and select [Check consumable supplies]
from the menu.
8. In the "Check consumable status" window, click the
[Reset] button of Pad ASSY Count.
The counter is reset to "0".
6.3. Replacing the Pick Roller
Replace the Pick roller following the procedure below.
1. Remove the document on the Paper chute.
2. Open the ADF while pulling the Cover open lever.
3. Adjust the Side guide to the "A5" size.
4. Remove the Sheet guide.
Pinch the Pickup tabs on the Sheet guide to pull the
Sheet guide to remove it.
5. Rotate the Pick roller bushing (left side) in the
direction of the arrow.
6. Remove the Pick roller with its shaft.
Slightly pull up the left part of the Pick roller shaft
(about 5mm), move it towards the left side, and then
raise it to remove from the scanner.
ADF
Sheet guide
Pickup tab
Pick roller
Pick roller shaft
S
S
ADF
Paper chute
Cover open lever
Pick roller
shaft
Pick roller
bushing
Pick roller
A5