2 WIRING
2.1 Wiring External Equipment
Connect external equipment to the MU-150C by referring to the drawings in this section. A
cable with connector at both ends is provided to connect equipment.
General-purpose monitor
To use the MU-150C as a general-purpose monitor, connect equipment with a mini D-SUB
15P connector. In this case do not connect a navigator to the NMEA port. Nav data is output
through the D-SUB 25P connector.
24 VDC
or 100-240 VAC
Ground
Terminal
Mini D-SUB
15P
CH-37: DISPLAY
CH-250: INTERFACE UNIT RGB OUT
FCV-1200 Series: INTERFACE UNIT RGB OUT
FCV-1500 Series: DISPLAY UNIT DISPLAY
GP/GD-280/380/680: DISPLAY UNIT EXT VIDEO
FR-1500 MK3 Series: Connector on RGB BUFFER
board in display unit
FR-1760DS: Connector on RGB BUFFER
board in display unit
Display unit, rear view, wiring using general-purpose cables
Note: When connecting a general-purpose monitor, use the following cable or the
equivalent:
Mini D-sub 15P: EVNPS05-50 ft, male-male, (max. 15 m)
Manufacturer: BlackBox Japan