Furuno DP-6 Network Card User Manual


 
3-7
3.4 Scan Channel Groups
The DP-6 can automatically control radio equipment through chan-
nel scanning. The radio equipment scans a number of channels
(according to your selection), stopping when your own ID code is
detected in an incoming signal. The transmitter is tuned to the cor-
responding transmitter frequency, the communication link is es-
tablished and the traffic is automatically exchanged. Scanning
resumes once the link is disconnected.
You may store a maximum of 10 scan groups, 20 channels per
group. Note that scanning is only possible in the ARQ and FEC
modes.
Registering Scan Channel Groups
1. Press function key [F5] followed by the [3] key to display the
Scan Entry screen.
Create
Change
Scan Entry
Scanning Group List
Scanning Set Up
Group Name :
Ch Dwell Time : 4.5 sec (2.7-4.5 sec)
Mode : AUTO ARQ FEC
Auto Search : OFF ON
No Channel Rx Freq Tx Freq Pass/Scan
1
2
3
4
5
6
Pass/Scan
Pass/Scan
Pass/Scan
Pass/Scan
Pass/Scan
Pass/Scan
Figure 3-8 Scan entry screen
2. If Create is not underlined, press [ ], [ ] and the [Enter] key
to underline it.
3. The cursor is on the Group Name line. Enter suitable group
name.
4. Press the [ ] key to advance the cursor to the CH Dwell Time
line. Enter channel dwell time in seconds. Dwell time is the
time in seconds the receiver waits on each channel in a scan
group before it selects the next frequency.