Furuno DP-6 Network Card User Manual


 
8-4
Station Name :
Frequency (T/R) : / (kHz) Comm Mode : Auto
Comm Status : Connect Send Lock Error Mark Space
1:File 2:Edit 3:Operate 4:Window 5:Station 6:System 7:WRU 8:HR 9:Over 10:Brea
k
1996-11-15 13:26:45.45 Caps Eng
Now Testing Tone Test 1 (All Char).
ABCDEFGHIJKLMNOPQRSTUVWXYZ1234567890-?:().,’=/+abcdefghijklmnopqrstuv
wxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZ1234567890-?:().,’=/+abcdefghijklmnopqrstuv
wxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZ
System
Lock Change Default
Setup
Figure 8-4 All characters test screen
Tone test 2 (Fox)
This test (continuously) checks for proper transmission of the test
message THE QUICK BROWN FOX JUMPS OVER THE LAZY
DOG 0123456789. In order to conduct the test call a station over
the ARQ or FEC mode.
Tone test 3 (Beta)
You may check for proper transmission of the idle signal β. Call
up a station using the ARQ mode.
Tone test 4 (Mark)
This test outputs the mark signal through the LINE OUT terminal,
where a frequency counter may be connected, to confirm its fre-
quency (1615 Hz).
Tone test 5 (Space)
Tone test 5 verifies the space signal frequency (1785 Hz).
Tone test 6 (BY)
This test verifies the frequency of the space B (1785 Hz) and mark
Y (1615 Hz), using a spectrum analyzer.