GarrettCom 6K16V Switch User Manual


 
Magnum 6K16V Managed Fiber Switch Installation and User Guide (06/04)
to the unit.
Power supply options are available to suit the 6K16V Switches to special high-
availability communications and/or heavy industrial-grade applications, including:
* -48VDC, 24VDC and 125VDC with single DC input,
* -48VDC, 24VDC and 125VDC with dual-source DC input,
See the Appendices of this manual for more details. Use an RFQ for other variations.
3.5 Alarm Contacts for monitoring internal power, and Software Traps
The Alarm Contacts feature, standard on Magnum 6K16V’s, provides two
Form C Normally Closed (NC) contacts to which the user can attach two sets of status
monitoring wires at the green terminal block. When this option is present, the terminal
block for Alarm Contacts is part of the Power Input panel in the Magnum 6K16’s case.
The AC or DC power input connection is in the same panel. A manual On-Off Switch for
power to the unit is not available on 6K16 units with the Alarm Contacts option, as these
two features occupy the same space in the case.
The first NC Alarm Contact (top position) is a “Software Alarm”, operated
by user settings in the MNS-6K software. The user can disable the Software Alarm
feature with a software configuration command if desired. When the Software Alarm is
enabled, the Form C Normally Closed (NC) contact is held close during normal software
operation. A user-defined software malfunction, such as an SNMP Trap or a Software
Security violation or an S-Ring Fault, causes the contact to open and thus trigger an
alarm in the user’s monitoring system
The second (bottom position) NC Alarm Contact is held close when there is
power on the main board inside of the 6K16. This provides a “Hardware Alarm” because
the NC contacts will open when internal power is lost, either from an external power
down condition or by the failure of the power supply inside of the Magnum 6K16
Switch. Useful info. about Alarm contacts:
1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply
2. The top two pins (1,2) are software operated
3. The bottom two pins (3,4) are hardware operated
4. By default it is NC (normally closed)
5. The software operation need to be enable
and set to get the Alarm traps. For detail
information about the Software Alarm and
software control of SNMP alarm traps, please
reference the Magnum MNS-6K Software
User Manual. (Chapter 19th).
The Alarm Contacts are on the
front left area (next to the DC power source)
of the Magnum 6K16V unit and is green in
color as shown in the picture.
Rela
y
Contacts
24